Model 980 Information

  • With an accuracy of +/-0.25%, the Model 980 provides reliable and repeatable results in critical high-speed applications. Features a tail pulley drive, weighted belt tension roller as well as a small radius nosebar. Built with 304 or 316 stainless steel, its open construction allows easy access for cleaning and maintenance. Material contact components of the weigh belt feeder are also easily removable or changeable for COP.
  • Materials of Construction

    • 304 Stainless Steel Parts, 316 Stainless Steel is Optional
    • All Non-Metallic Parts are FDA Approved

    Power Requirements

    • 115V ±10% Single Phase, 50/60 Hz
    • Optional Voltages / Phase / Hz

    Variable Speed Drive

    • AC or DC Motor • HP from 0.25 - 1.0 HP
    • SCR or VFD Configurations

    Accuracy & Repeatability

    • Standard Accuracy is better than ±0.25%
    • Standard Repeatability is better than ±1.0%
    • Feedrate Turndown is 40:1

    Common Options

    • Manual Material Cut-off Gate (Inlet)
    • Flexible Inlet and Discharge Connections
    • Calibration Test Chain
    • Abrasion Resistant Design
    • Automatic Sample Valve

  • For Spare parts for this model and more click here